  • som svar på: Room sensor #7659
    ekonttan
    Deltagare

    It would seem that 307/308 is for totally different purpose, EVT Timer, so there is something else wrong with my installation.

    Any other suggestion or setting that I should enable on the Thermia itself? Should I order replacement temp-cable?

    som svar på: Room sensor #7658
    ekonttan
    Deltagare

    Need to fiddle a bit more.

    I tried to swap 303/304 but no avail.

    So I still can’t get the room sensor to work, maybe is is some other terminals? Any suggestions for finding diagram or confirmation them to be 303/304 for ”Diplomat Duo Optimum 8” I would be very grateful!

    I only found obscure mention about the possibility to add room temperature sensor to this model in the manual, but no diagrams.

    Only one diagram/picture behind the cover of the machine itself:

    SELV 5V
    406: 303, 304
    50: 305, 306
    408: 307, 308

    54: 311, 312
    55: 325, 326

    Physically 307/308 are the only other free slots in the same block.

    som svar på: Room sensor #7656
    ekonttan
    Deltagare

    Ok, I’ll try to that.

    What I already noticed, is that for example

    set {”INDR_T”:21}

    changes the value on ThermIQ-room’s own small display to that value, but that is not visible on Thermia itself or on ThermIQ2 webserver.

    som svar på: Room sensor #7654
    ekonttan
    Deltagare

    Ok, thanks. I also now get the benefit of the room sensor with you explanation as I noticed it simply changed the target, the same value that I was able to change directly from my Thermia Diplomat Duo Optimum.

    I have to check why I don’t get this 20.5. It might be wrong connection as I simply used terminal 303/304 since I couldn’t find any details for my Thermia model (Thermia Diplomat Duo Optimum 8).

    som svar på: Room sensor #7651
    ekonttan
    Deltagare

    Ok, thanks! How to check that room sensor is connected correctly? How to test it ie. how to set indoor temp, not just indoor target temp?

    • Det här svaret redigerades för 2 år, 7 månader sedan av ekonttan.